Most of the site will reflect the ongoing surgical activity of Prof. Munir Elias MD., PhD. with brief slides and weekly activity. For reference to the academic and theoretical part, you are welcome to visit
neurosurgery.tv
Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
24-APRIL-2014 YAHYA HUSSEIN AL-AQEL 65
YEARS EXTRUDED DISC L4-5 WITH LEFT FORAMINAL OCCLUSION.
Anamnesis
The patient came to the clinic 21-April-2014
complaining of left sciatica for 10 years with
exacerbation the last 5 months with numbness big
toe left foot. MRI lumbar spine bad quality,
done 09-April-2014 showing extruded disc L4-5
with left foraminal occlusion.
On examination; the patient is limping with
exaggerated scoliotic stance. SLRS was 90
degrees with pain in the left. There is weak
dorsiflexion left foot -3/5 with hypalgesia left
L4,5and S1 roots. MRI of the lumbar
spine repeated the same day confirming the
previous data with left far-lateral extrusion.
Using the C-arm, the L4-5 level identified.
Using MICRODISCXS system and VITOM Carl Storz
attachments, foraminotomy left L5
root was performed and the huge extruded disc
was removed lateral to the axilla. Left sided
cleaning L4-5 disc space. The root hanging free.
Routine closure of the wound.
Smooth postoperative recovery. The power of the
left foot became normal.
Medicon MICRODISCXS set.
Comments
The patient has still have an estimated
postoperative recurrence around 7%, because the
disc space is still not shallow.
The MICRODISCXS system is just a retractor
system, it must be used in conjunction with
VITOM to obtain better video recording.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Leica HM500
The World's first and the only Headmounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .