Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
09-DECEMBER-2004 ZAYED KHALAF AL-DAAJA 41 YEARS
HUGE EXTRUDED DISC L4-5.
Anamnesis
The patient's brother came to the clinic 08-December-2004
telling that the patient is
complaining of severe LBP with bilateral
sciatica for 6 days. MRI lumbar spine performed
04-December-2004 showing very huge extruded disc
L4-5.
On examination before surgery: The patient is in agonizing
pain, limping with exaggerated scoliotic stance.
There is weak dorsiflexion both feet 2/5,
planterflexion same foot 3/5. SLRS was 10 degrees with pain
both
sides.
Decompressive laminectomy L4-5
with bilateral L5 foraminotomy
with removal of the huge extrusion from right
subaxillary approach and bilateral
intradiscal cleaning of L4-5. Due to severe
compression, the tiny dura was stitched by nylon 6
zero to avoid postoperative CSF leak. The patient was put in
Reverse Trendelenburg position with Valsalva
maneuver and hyperventilation. No CSF leak. Routine
closure of the wound.
Smooth postoperative recovery.
The power of the feet improved.
He was sent to the ward.
Follow Up
The patient came to the clinic 20-December-2004
with weak dorsi and planterflexion right foot
4/5. The patient then came 24-July-2012
complaining of left sciatica with full
power of the right foot and weak dorsiflexion
left foot 4/5. He was sent for investigations,
but he never showed up again.
Comments
There is still an estimated postoperative
disc recurrence around 7%, since the disc space is not
completely shallow.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .