Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
05-JUNE-2016 ABDEL-MAJID DAWOOD AL-FALAH 36 YEARS
EXTRUDED DISK L5-S1 WITH RIGHT DOWNWARD MIGRATION.
Anamnesis
The patient came to the clinic
31-May-2016 complaining of LBP and right
sciatica for 2 years with bilateral sciatica for
45 days more the right. MRI
lumbar spine performed 02-May-2016 showing
huge extruded disc L5-S1 with with right
foraminal occlusion with small extrusion L3-4
left side.
On examination: the patient is limping with
exaggerated scoliotic
stance. SLRS was 65 degrees both sides with pain. There is weak
dorsiflexion right foot 4/5 and hypalgesia right L5 and
S1 territories.
The patient was sent for investigations and
repeat MRI showing the small extrusion of L3-4
left and extruded disc L5-S1 with right downward
migration. Dynamic studies were negative. ESR 30
mm/h and CRP was 40 mg/L. The patient was
started in antibiotics immediately to prevent
the hidden source of infection.
Using the C-arm, the
L5-S1 level was identified and
foraminotomy right S1 root was achieved with
preservation and reflection of the ligamentum
flavum to the left trying to keep the epidural
fat. The extruded disk was removed from
right side and right sided cleaning of L5-S1 was
performed. The disc material was soft in
consistency. Using MultiGen, stimulation of
right
S1 root was achieved with
0.9 V. A
bipolar pulsed mode
RF with 42 Celsius, 240 sec, 2 Hz and 20 msec
duration to right S1 roots was achieved using
2 bended catheters 10 mm exposed length. Further
motor stimulation done to the same root and the
response was 0.8 V. Routine closure of the
wound.
Smooth postoperative recovery. The patient
is sciatica free. The power of right foot
normalized and he was sent to the ward.
MultiGen
Comments
The patient still have an estimated
postoperative recurrence around 7%, because the disc space
is still not shallow.
This is the 64th case using the BPRF mode
with MultiGen. This procedure regained routine acceptance it
became
a usual part of the spine surgery.
Click here for
reference.
It still unclear to evaluate the differences of pre
and post application motor responses. The only sure thing
that it tell that the electrodes did not migrate during the
procedure and the nerve is functioning properly.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Headmounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .