Most of the site will reflect the ongoing surgical activity of Prof. Munir Elias MD., PhD. with brief slides and weekly activity. For reference to the academic and theoretical part, you are welcome to visit  neurosurgery.tv

Functional Neurosurgery
functionalneuro.surgery
Functionalneurosurgery.net

IOM Sites
iomonitoring.org
operativemonitoring.com

Neurosurgical Sites
neurosurgery.art
neurosurgery.me
neurosurgery.mx
skullbase.surgery

Neurosurgical Encyclopedia
neurosurgicalencyclopedia.org

Neurooncological Sites
acousticschwannoma.com
craniopharyngiomas.com
ependymomas.com
gliomas.info
gliomas.uk
meningiomas.org
neurooncology.me
pinealomas.com
pituitaryadenomas.com 

Neuroanatomical Sites
humanneuroanatomy.com 
microneuroanatomy.com

Neuroanesthesia Sites
neuro-anesthessia.org

Neurobiological Sites
humanneurobiology.com

Neurohistopathological
neurorhistopathology.com

Neuro ICU Site
neuroicu.info

Neuroophthalmological
neuroophthalmology.org

Neurophysiological Sites
humanneurophysiology.com

Neuroradiological Sites
neuroradiology.today

NeuroSience Sites
neuro.science

Neurovascular Sites
vascularneurosurgery.com

Personal Sites
cns.clinic

Spine Surgery Sites
spine.surgery
spondylolisthesis.info
paraplegia.today

Stem Cell Therapy Site
neurostemcell.com


 

Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses


 

Multigen RF lesion generator .

07-JJULY-2015  BUSHRA NABEEL ZAYANI  37 YEARS  PROGRESSING HYDROCEPHALUS DUE TO TROUBLESHOOTING VPS.

 

 

Anamnesis

bullet

The patient was operated by me 12-January-2015 for progressive hydrocephalus by inserting medium pressure VPS. The patient continued to complain after then with lesser degree. MRI of the brain and CT-scan was done 23-April-2015 showing short ventricular tip of the shunt, that when it evacuate the CSF the tip becoming non functioning, for what it was decided to replace this part with longer one.

bullet

The old incision refreshed and extended posterior to expose the bur hole site and the proximal connection of the reservoir. The reservoir is placed far from the bur hole, the reason why the ventricular end was short. The ventricular part of the shunt was removed and another one with different direction more vertical to the plane and projecting to the right pupil and the right inner ear planes. It was pushed 7 cm and the CSF came clear. Another 3 cm were advanced without stylette. The ventricular part was connected to the reservoir aided with 4 zero nylon stitch. Routine closure of the wound.

bullet

Smooth postoperative recovery. The patient was sent to the floor.

Comments  

bullet

The patient with far positioned reservoir caused the ventricular tip to be short. All the holes of the ventricular tip must be in the ventricular cavities to work adequately.

 

Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.


Inomed Riechert-Mundinger System, with three point fixation is the most accurate system in the market. The microdrive and its sensor gives feed back about the localization.


Inomed MER system

 

ISIS 32 channel Inomed IOM system for intraoperative neurophysiologic navigation running since 2007.

 

Leica HM500

Leica HM500
The World's first and the only Headmounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and documentation.

TRUMPF TruSystem 7500

After long years TRUMPF TruSystem 7500 is running with in the neurosuite at Shmaisani hospital starting from 23-March-2014

 


Back Up!

Notice: Not all operative activities can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also escaped from the plan .

WELCOME TO AL-SHMAISANI HOSPITAL

 

 

 

© [2015] [CNS CLINIC - NEUROSURGERY - JORDAN]. All rights reserved