07-JJULY-2015 BUSHRA NABEEL ZAYANI 37 YEARS
PROGRESSING HYDROCEPHALUS DUE TO TROUBLESHOOTING VPS.
Anamnesis
The patient was operated by me
12-January-2015 for progressive
hydrocephalus by inserting medium pressure VPS.
The patient continued to complain after then
with lesser degree. MRI of the brain and CT-scan
was done 23-April-2015 showing short ventricular
tip of the shunt, that when it evacuate the CSF
the tip becoming non functioning, for what it
was decided to replace this part with longer
one.
The old incision refreshed and extended
posterior to expose the bur hole site and the
proximal connection of the reservoir. The
reservoir is placed far from the bur hole, the
reason why the ventricular end was short. The
ventricular part of the shunt was removed and
another one with different direction more
vertical to the plane and projecting to the
right pupil and the right inner ear planes. It
was pushed 7 cm and the CSF came clear. Another
3 cm were advanced without stylette. The
ventricular part was connected to the reservoir
aided with 4 zero nylon stitch. Routine closure
of the wound.
Smooth postoperative recovery. The patient was
sent to the floor.
Comments
The patient with far positioned reservoir
caused the ventricular tip to be short. All the holes of the
ventricular tip must be in the ventricular cavities to work
adequately.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
ISIS 32 channel Inomed IOM system for intraoperative
neurophysiologic navigation running since 2007.
Leica HM500
The World's first and the only Headmounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .