Most of the site will reflect the ongoing surgical activity of Prof. Munir Elias MD., PhD. with brief slides and weekly activity. For reference to the academic and theoretical part, you are welcome to visit  neurosurgery.tv

Functional Neurosurgery
functionalneuro.surgery
Functionalneurosurgery.net

IOM Sites
iomonitoring.org
operativemonitoring.com

Neurosurgical Sites
neurosurgery.art
neurosurgery.me
neurosurgery.mx
skullbase.surgery

Neurosurgical Encyclopedia
neurosurgicalencyclopedia.org

Neurooncological Sites
acousticschwannoma.com
craniopharyngiomas.com
ependymomas.com
gliomas.info
meningiomas.org
neurooncology.me
pinealomas.com
pituitaryadenomas.com 

Neuroanatomical Sites
humanneuroanatomy.com 
microneuroanatomy.com

Neuroanesthesia Sites
neuro-anesthessia.org

Neurobiological Sites
humanneurobiology.com

Neurohistopathological
neurorhistopathology.com

Neuro ICU Site
neuroicu.info

Neuroophthalmological
neuroophthalmology.org

Neurophysiological Sites
humanneurophysiology.com

Neuroradiological Sites
neuroradiology.today

NeuroSience Sites
neuro.science

Neurovascular Sites
vascularneurosurgery.com

Personal Sites
cns.clinic

Spine Surgery Sites
spine.surgery
spondylolisthesis.info
paraplegia.today

Stem Cell Therapy Site
neurostemcell.com


Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses


Multigen RF lesion generator .

14-SEPTEMBER-2015  BUSHRA NABEEL ZAYANI  37 YEARS  STILL MALFUNCTIONING VPS.

 

Anamnesis

bullet

The patient was operated by me the second time for repositioning the ventricular end of the VPS 07-July-2015 and continued to complain of the same headache and control MRI and CT-scan confirmed that despite the shunt was in the ventricular system with sufficient length, but the hydrocephalus still the same. It seems that the patient is not responding to the medium pressure VPS and it was decided to change it to low pressure brand.

bullet

The old reservoir exposed. It is functioning with clear CSF coming. The reservoir was removed and the ventricular end was withdrawn about 8 mm. A low pressure regular PS Medical reservoir was connected. Routine closure of the wound.

bullet

Smooth postoperative recovery. The patient was sent to the ward.

 

 

 

Comments  

bullet

The patient hydrocephalus is not responding to the medium pressure type, for what low pressure reservoir was applied.

bullet

It is very rare that the patient showed complete non-response to medium pressure VPS as in this case.

Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.


Inomed Riechert-Mundinger System, with three point fixation is the most accurate system in the market. The microdrive and its sensor gives feed back about the localization.


Inomed MER system

Leica HM500

Leica HM500
The World's first and the only Headmounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and documentation.

TRUMPF TruSystem 7500

After long years TRUMPF TruSystem 7500 is running with in the neurosuite at Shmaisani hospital starting from 23-March-2014

 


Back Up!

Notice: Not all operative activities can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also escaped from the plan .

WELCOME TO AL-SHMAISANI HOSPITAL

 


View Larger Map
 

© [2015] [CNS CLINIC - NEUROSURGERY - JORDAN]. All rights reserved