Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
11-APRIL-2016 FAYSAL SHAMSI MUSA 47
YEARS HUGE RECURRENT DISC L4-5 WITH LEFT FORAMINAL AND
EXTRAFORAMINAL OCCLUSION.
Anamnesis
The patient was operated by me for extruded disc
L4-5
27-December-2008. The patient was doing will
until he came to the clinic 07-April-2016
complaining of LBP with left sciatica for 1 day
agonizing down to the left knee with numbness
all toes left foot with positive cough sign. The
patient now has arterial hypertension in Coveram
10/5 once daily.
On examination: the patient is limping with
exaggerated scoliotic
stance. SLRS was
30 degrees with pain in the left. There
is weak dorsi and planterflexion left
foot 3/5. Hypalgesia both left L5, S1 roots.
The patient was sent for investigations and MRI
lumbar spine performed 09-April-2015 showing
huge recurrence of L4-5 with left foraminal and
extraforaminal occlusion. Dynamic studies were
normal and Lab investigations showed ESR 50 mm/h
with CRP 6 mg/L.
The old incision refreshed
and dissection carried out down to the left
upper corner of the previous bone defect and
neurolysis of the left L5 root was achieved. The
extruded disc was removed lateral to the axilla
and the far lateral extraforaminal part removed.
Left
sided
cleaning of the disc space was achieved. Using MultiGen, a
bipolar pulsed mode
RF with 42 Celsius, 240 sec, 2 Hz and 20 msec
duration to left L5 root was achieved using 2 bended catheters 10 mm exposed length.
The electrodes were put both lateral to the
axilla. Stimulation of the root with 4 V showed slight
response, but with 5 V brisk response. Routine closure of the
wound.
Smooth postoperative recovery.
The power of left foot became normal. The patient
is sciatica free. He was sent to the ward.
MultiGen
Comments
The patient still having an estimated
postoperative recurrence around 7%, because the disc space
is still not shallow.
This is the 49th case using the BPRF mode
with MultiGen. This procedure regained routine acceptance it
became
a usual part of the spine surgery.
Click here for
reference.
If there is scar, it hard to predict the
correlation between the root response to stimulation
amplitude and the postoperative recovery. All the modalities
of stimulation were tested, monopolar, bipolar and at times
even 8 V did not show any response. Only direct contact to
healthy parts of the root gave response. The scar blocked
the motor response even to high currents.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Headmounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .