Most of the site will reflect the ongoing surgical activity of Prof. Munir Elias MD., PhD. with brief slides and weekly activity. For reference to the academic and theoretical part, you are welcome to visit
neurosurgery.tv
Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
13-JULY-2015 HIND MUHAMED SALAH 55 YEARS
EXTRUDED DISC C6-7 WITH RIGHT FORAMINAL OCCLUSION.
Anamnesis
The patient was operated by me
28-March-2006
for extruded disc C5-6 then for right CTS, then
left CTS 16-February-2015. MRI cervical spine
done 02-April-2015 showing small extruded disc
C4-5 and C5-6. There was no sensory motor
deficit of both upper limbs. The patient then
came 12-July-2015 complaining of agonizing neck
pain with inability to move the head to all
directions with shooting pain to the right upper
limb.
On examination: The patient is in agonizing pain
with weak grip and extension of the right hand
4/5 and right triceps 3/5. There is also weak
dorsiflexion right foot.
MRI of the cervical spine performed today,
showing extruded disc C6-7 with left foraminal
occlusion with small extruded disc C4-5, bony
hard to the left. The previously operated disc
of C5-6 disappeared as the patient ha
assimilation of C5-6.
The old incision disappeared, for what the
supposed level was was identified and discectomy
of C6-7 was performed with removal of the
extrusion at the right foramen. The dura was
seen at the entire posterior aspect of the disc
space. A compact anatomical cage 5 mm
inserted to the disc space and fusion of C6-7
was achieved using Atlantis one level plate 25
mm with 4 screws 4x15 mm. Routine closure
of the wound.
Smooth postoperative recovery. The patient was
sent to the floor.
Comments
The patient had small PCD C6-7 which was
silent 2 months ago. The last 3 days fresh extrusion of this
area to the right foramen was severely compressing the root,
which necessitate the surgery.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
ISIS 32 channel Inomed IOM system for intraoperative
neurophysiologic navigation running since 2007.
Leica HM500
The World's first and the only Headmounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .