Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
03-NOVEMBER-2024 IBRAHEEM MABKHUT MUHAMED 34 YEARS
NON-FUNCTIONING VPS INSERTED 21 YEARS AGO.
Anamnesis
The patient a Yemeni citizen was operated by me
13-April-2003 for progressive hydrocephalus,
after what he recovered and disappeared.
The patient then came 31-October-2024
complaining of headache for one month with
somnolence. Check CT-scan was done 2017 and 2018
were normal with ventricles normal in shape and
the shunt in place. CT-scan done 22-October-2024
showing widened ventricles. The patient is in
somnolence with blurred vision. The pump of the
device is not functioning. He was sent to X-rays
to rule out rupture of the device. The device is
intact and reaching the pelvic cavity. CRP was
29 mg/L. The family telling that he felt
down yesterday for what MRI of the brain done to
rule out subdural hematoma and admitted
02-November-2024. Mannitol 25 mg I/V
started Q 8 h. with Foley's catheter and
antibiotics started.
The cranial and abdominal parts of the shunt
were exposed. The intra-abdominal tip was
showing very small amount of clear CSF.
Inspection of the reservoir, showed intact
ventricular part, but the distal end had a small
gap between the tube and reservoir. Trail to use
the old tube to obtain the tunneling failed and
even removal of the tube from above and below
was impossible due to calcifications around the
tube that one third above and one third fro
below ere removed and the middle third was left
in place. Using passer the new Medtronic PS
Medical delta medium pressure was inserted to
the ventricular part. The coming CSF was in huge
quantity. It was possible to see the omintum,
but was scarous. Routine closure of the wounds.
The patient showed delayed recovery and was sent
to the ward. The patient was seen 5 hours after
surgery and vision was preserved and the level
of consciousness was better.
FOLLOW UP
Too early now.
Comments
The patient has has progressive
hydrocephalus which could lead to blindness if left without
surgical interference.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
LooksCam II Xenosys in the run starting from 14-March-2021 with
SheerVision TTL x4 magnification.
Cios-Spin flat panel in the run.
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .