Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
14-JUNE-2016 KHALEEL KHADER HAMMADY 46 YEARS
EXTRUDED DISC L5-S1 WITH RIGHT DOWNWARD MIGRATION.
Anamnesis
The patient came to the clinic
12-June-2016 complaining of LBP and right
sciatica for 10 days with difficult standing in
chair and numbness of the big toe right foot. MRI
lumbar spine performed 12-June-2016 showing
huge extruded disc L5-S1 with with right
foraminal occlusion and downward migration.
On examination: the patient is now not limping with
no scoliotic
stance. SLRS was 30 degrees right side with pain. There is weak
dorsiflexion right foot 4/5 and hypalgesia right L5 and
S1 territories. Absent right AJ.
Using the C-arm, the
L5-S1 level was identified and
foraminotomy right S1 root was achieved with
preservation and reflection of the ligamentum
flavum to the left trying to keep the epidural
fat. The extruded disk was removed from
right side and right sided cleaning of L5-S1 was
performed. The extruded disc material was hard in
consistency. Using MultiGen, bipolar motor stimulation of
right
S1 root was achieved with 1.4 V. A
bipolar pulsed mode
RF with 42 Celsius, 240 sec, 2 Hz and 20 msec
duration to right S1 roots was achieved using
2 bended catheters 10 mm exposed length. Further
motor stimulation done to the same root and the
response was 1.4 V. Routine closure of the
wound.
Smooth postoperative recovery. The patient
is sciatica free. The power of right foot
normalized and he was sent to the ward.
MultiGen
Comments
The patient still have an estimated
postoperative recurrence around 7%, because the disc space
is still not shallow.
This is the 66th case using the BPRF mode
with MultiGen. This procedure regained routine acceptance.
It
became
a usual part of the spine surgery.
Click here for
reference.
It still unclear to evaluate the differences of pre
and post application motor responses. The only sure thing
that it tell that the electrodes did not migrate during the
procedure and the nerve is functioning properly. Here there
was no difference of power of motor stimulation before and
after the procedure.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Headmounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .