Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
15-AUGUST-2016 MUHAMED HASAN BADER 37 YEARS
HUGE EXTRUDED DISK L4-5 CENTRAL MORE TO THE LEFT.
Anamnesis
The patient came to the clinic
13-August-2016 complaining of LBP for 2 years
with bilateral sciatica more to the left for 5
months with radiation to posterior aspect of the
left thigh.
On examination: the patient is not limping with
no scoliotic stance. SLRS was 80 degrees
without pain. There is weak
dorsiflexion left foot -4/5 with difficult
setting.
The patient was sent for investigations and MRI
lumbar spine performed 13-August-2016 showing
huge extruded central disk L4-5 more to the
left. Dynamic studies and lab investigations
were uneventful.
The
L4-5 level was identified and
decompressive laminectomy L4 and
L5 was done. Foraminotomy both L5 roots was achieved. The extruded disk was removed from
left side and left sided cleaning of L4-5 was
performed. The other side was inspected and not
violated. Using MultiGen, bipolar motor stimulation of
right L5 root was achieved with 1.5 V in the
right root and 0.9 V in the left root. A
bipolar pulsed mode
RF with 42 Celsius, 240 sec, 2 Hz and 20 msec
duration to both L5 roots was achieved using
4 bended catheters 10 mm exposed length. Further
motor stimulation done to the same roots and the
response was 1.3 V in the right and 0.9 V to the
left. Routine closure of the
wound.
Smooth postoperative recovery. The power of
left foot normalized and he was sciatica free. He was sent to the ward.
MultiGen
Comments
The patient still have an estimated
postoperative recurrence around 7%, because the disc space
is still not shallow.
This is the 70th case using the BPRF mode
with MultiGen. This procedure regained routine acceptance.
It
became
a usual part of the spine surgery.
Click here for
reference.
It still unclear to evaluate the differences of pre
and post application motor responses. The only sure thing
that it tell that the electrodes did not migrate during the
procedure and the nerve is functioning properly. Here there
was slight decrease of the threshold of stimulation power of motor stimulation
after the procedure in the right side and without changes in
the left.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Headmounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
ILLICO minimally retractor system
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .