Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
01-MARCH-2016 REEM HUSSEIN AL-FATTAL 28 YEARS
RECURRENT DISC L4-5 WITH RIGHT FORAMINAL OCCLUSION.
Anamnesis
The patient was operated elsewhere
17-February-2013 for PLD L4-5 for left sciatica,
then came to me and was operated for huge
extruded disc C5-6
04-July-2014. She was using crutches and
stopped using it one year ago. The patient then came to the clinic
02-February-2016
telling that she improved, but still complaining
of right sciatica with LBP with
numbness left S1 territory.
On examination: the patient is not limping with
no scoliotic
stance. SLRS was 70 degrees with pain in the
right. There is weak dorsiflexion
right foot -4/5 and
planterflexion same foot 4/5 and hypalgesia
left S1 territory.
The patient was sent for MRI lumbar spine. It
was preformed 20-February-2016
showing recurrent extruded disc L4-5 with right foraminal occlusion.
Dynamic studies ruled out overmobility.
The old incision refreshed.
The dissection was carried out over the scar.
Right L5 foraminotomy. The recurrent extrusion
was removed lateral to the axilla. Right sided
intradiscal cleaning L4-5 disc space. Using MultiGen, a
bipolar pulsed mode
RF with 42 Celsius, 240 sec, 2 Hz and 20 msec
duration to right L5 root was achieved using
2 bended catheters 10 mm exposed length. The
previous ugly scar was removed. Routine closure of the
wound.
Smooth postoperative recovery.
The power of left foot became normal. The patient
is sciatica free. She was sent to the ward.
MultiGen
Comments
The patient having an estimated
postoperative recurrence around 0%, because the disc space
completely collapsed.
This is the 41st case using the BPRF mode
with MultiGen. This procedure regained routine acceptance it
became
a usual part of the spine surgery.
Click here for
reference.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Headmounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .