Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
03-JUNE-2016 SULTAN ABDEL-JAWAD ATEF 42 YEARS
HUGE EXTRUDED DISC L5-S1 BROAD BASED MORE TO THE LEFT.
Anamnesis
The patient came to the clinic
02-June-2016 complaining of LBP with left sciatica for
1 month with inability to walk. MRI
lumbar spine performed 12-May-2016 showing
huge extruded disc L5-S1 with wide-based more to
the left. The patient is a known diabetic for 2
months.
On examination: the patient is in agonizing
pain, limping with
exaggerated scoliotic
stance. SLRS was 60 degrees in the right with
pain and 30 degrees left side with more pain. There is weak
dorsiflexion left foot 4/5 and planterflexion
both feet 4/5. There is hypalgesia left L5 and
S1 territories with absent AJ in the left.
Using the C-arm, the
L5-S1 level was identified and
foraminotomy left S1 root was achieved with
preservation and reflection of the ligamentum
flavum to the right trying to keep the epidural
fat. The extruded disk was removed from
left side and left sided cleaning of L5-S1 was
performed. The disc material was soft, watery as
having an inflammatory process. Using MultiGen, stimulation of left
S1 root was achieved with
2.1 V. A
bipolar pulsed mode
RF with 42 Celsius, 240 sec, 2 Hz and 20 msec
duration to both L5 and right S1 roots was achieved using
2 bended catheters 10 mm exposed length. Further
motor stimulation done to the same root and the
response was 1.8 V. Routine closure of the
wound.
Smooth postoperative recovery. The patient
is sciatica free. The power of both feet
normalized and he was sent to the ward.
MultiGen
Comments
The patient still have an estimated
postoperative recurrence around 7%, because the disc space
is still not shallow.
This is the 63rd case using the BPRF mode
with MultiGen. This procedure regained routine acceptance it
became
a usual part of the spine surgery.
Click here for
reference.
It still unclear to evaluate the differences of pre
and post application motor responses. The only sure thing
that it tell that the electrodes did not migrate during the
procedure and the nerve is functioning properly.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Headmounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .