Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses
Multigen RF lesion generator .
23-JANUARY-2017 YOUSEF MUSA ALI 54 YEARS HUGE EXTRUDED
DISC L5-S1 WITH RIGHT DOWNWARD MIGRATION.
Anamnesis
The patient came to the hospital 21-January-2017
complaining of LBP for three years with
exacerbation last 3 months and right sciatica
and agonizing pain for 3 weeks. MRI lumbar spine performed
the same day showing huge extruded disc L5-S1
with
right downward migration. The patient is a known
diabetic for 4 years in treatment.
On examination, the patient is in agonizing
pain, limping with exaggerated scoliotic stance. SLRS
was 33 degrees right side with pain. There is weak
right foot dorsiflexion 4/5, dorsiflexion same
foot 4/5 and hypalgesia right S1 territory.
Right S1 foraminotomy
was achieved. The Level of the L5-S1 was
identified. The extruded disk was removed
lateral to the axilla under the S1 root. Right sided cleaning of L5-S1 was
performed. Using MultiGen, bipolar motor stimulation of
the right S1 was achieved with 0.8 V. A
bipolar pulsed mode
RF with 42 Celsius, 240 sec, 2 Hz and 20 msec
duration to the right S1 root was achieved using
2 bended catheters 10 mm exposed length. Further
motor stimulation done to the same root and the
response was 0.6 V with more
brisk response. Routine closure of the
wound.
Smooth postoperative recovery. The power of
the right foot improved and he was sciatica free.
He was sent to the ward.
MultiGen
Comments
The patient still having an estimated
postoperative recurrence around 7%, because the disc
space is still not shallow.
This is the 102d case using the BPRF mode
with MultiGen. This procedure regained routine acceptance.
It became a usual part of the spine and peripheral nerves
surgery.
Click here for
reference.
It still unclear to evaluate the
differences of pre and post application motor responses. The
only sure thing that it tell that the electrodes did not
migrate during the procedure and the nerve is functioning
properly. Here there was considerable improvement of the threshold of
stimulation power of motor stimulation after the BPRF.
With accumulation of data, it became
clear that the irritated nerve with aberrant currents
running in the C fibers up, not only causing no change or elevation of
the required voltage to achieve motor response, but they could cause the preoperative
weakness. Ablation of such currents results in facilitation
of the motor response and improvement of function with
disappearance of pain.
It is unclear why the roots have several
motor response with different patients, despite the fact
that the neurological status is the same and the anaesthesia
protocol also the same. In this case adhesions could be a
factor for initial high voltage requirement to achieve motor
response.
Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.
Inomed Riechert-Mundinger System, with three point
fixation is the most accurate system in the market. The microdrive and
its sensor gives feed back about the localization.
Inomed MER system
Leica HM500
The World's first and the only Headmounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and
documentation.
After long years TRUMPF TruSystem 7500 is running with in the neurosuite at
Shmaisani hospital starting from 23-March-2014
Notice: Not all operative activities
can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also
escaped from the plan .